Home ProductsPlastic Water Meters

High accuracy Rosemount Analytical 499 series / measurement analysis instruments

China Beijing Water Meter Co.,Ltd. certification
China Beijing Water Meter Co.,Ltd. certification
Cooperation is very satisfactory and the Company of the past few years, we are very willing to continue long-term cooperation.

—— Dean

The company considerate after-sales service ,And try their best to meet the requirement of customers. We will be a long-term cooperation.

—— Albert

Easy to talk with, very professional and fast service, the quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

I'm Online Chat Now

High accuracy Rosemount Analytical 499 series / measurement analysis instruments

High accuracy Rosemount Analytical 499 series / measurement analysis instruments
High accuracy Rosemount Analytical 499 series / measurement analysis instruments

Large Image :  High accuracy Rosemount Analytical 499 series / measurement analysis instruments

Product Details:
Place of Origin: USA
Brand Name: Rosemount
Certification: CSA Explosion-proof FM Explosion-proof, Dust Ignition-proof ATEX Flame-proof
Model Number: 499AOZ / 499ADO / 499TRDO
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Packaging Details: In carton or as customer’s requirement
Delivery Time: 4~6weeks
Payment Terms: T/T, L/C, PayPal, Western Union, Cash, Escrow
Supply Ability: 2000pcs
Detailed Product Description
High Light:

PH transmitter

,

measurement analysis instruments

Rosemount  Analytical 499AOZ / 499ADO / 499TRDO Ozone and Dissolved Oxygen Sensors - VP available

 

Quick Detail:

 

    · Manufactured by Rosemount Analytical

· Rugged construction

· Easily replaceable membrane

· Automatic temperature compensation

· Automatic pressure equalization

· High accuracy

· Variopol connector available

 

 

Description:

 

Rosemount Analytical 499 series dissolved oxygen, ozone, and chlorine sensors work with Rosemount Analytical analyzers to provide high accuracy dissolved oxygen, dissolved ozone and chlorine readings. With a wide range and numerous mounting options, 499 series sensors are excellent choices for a wide range of applications.

The 499 series are membrane-covered amperometric sensors. Maintenance and calibration is fast and easy with no special tools required. Because the rate of diffusion of oxygen through the membrane depends on temperature, an integral Pt100 RTD measures the temperature to compensate for membrane permeability. Response to pressure changes has also been minimized by incorporating a system which balances pressure inside the sensor with sample pressure. The Model 499 sensor is available with a Variopol (VP) water-tight connector.

The Rosemount Analytical 499 series dissolved oxygen, ozone and chlorine sensors are available in multiple models:

Rosemount Analytical 499ADO Dissolved Oxygen Sensor

The Model 499ADO sensor is intended for the continuous determination of dissolved oxygen between 0-20 ppm. The primary application is aeration basins in municipal and industrial wastewater treatment plants. The 499ADO has a basic accuracy of ±0.2 ppm at 25°C and a repeatability: ±0.05 ppm at 25°C. Response time is 25 sec to 63% of final reading at 25°C. The 499ADO is suitable for temperatures from 32 to 122°F and pressures from 0 to 65 psig.

Rosemount Analytical 499ATrDO Trace Dissolved Oxygen Sensor

The Model 499ATrDO sensor is intended for the determination of trace (ppb) levels of dissolved oxygen in steam power plants and high purity cooling water. The 499AtrDO has a range of 0.1 ppb to 20 ppm with basic accuracy of ±1 ppb (for samples under 20 ppb) or ±5% (for samples over 20 ppb). Response time is under 20 sec to 90% of final reading at 25°C. The 499ATrDO is suitable for temperatures from 41 to 113°F and pressures from 0 to 65 psig.

Rosemount Analytical 499AOZ Dissolved Ozone Sensor

The Model 499AOZ sensor is intended for the continuous determination of dissolved ozone. The primary application is ozonation basins in municipal water filter plants. Ozone is also used as a disinfectant in bottling and food processing plants. The 499AOZ has a range of 0 to 3 ppm with a repeatability of ±2% of reading at constant temperature. The response time is 30 sec to 90% of final reading at 25°C. The 499AOZ is suitable for temperatures from 32 to 122°F and pressures from 0 to 65 psig. Because ozone standards do not exist, the sensor must be calibrated against the results of a laboratory test run on a grab sample of the process liquid.

Rosemount Analytical 499ACL-01 Free Chlorine Sensor

The Model 499ACL-01 sensor is intended for the continuous determination of free chlorine (hypochlorous acid plus hypochlorite ion) in water. The primary application is measuring chlorine in drinking water. The sensor can also be used to monitor dechlorination processes. The sensor requires no acid pretreatment and can measure free chlorine in samples from 6.0 to 9.5 pH and in some cases 10.0. Accuracy depends on the accuracy of the chemical test used to calibrate the sensor. Response time is 22 sec to 95% of final reading at 25°C.

Rosemount Analytical 499ACL-02 Total Chlorine Sensor

The Model 499ACL-02 sensor is really an iodine sensor. The iodine comes from the reaction between halogen oxidants in the sample and the acetic acid/potassium iodide reagent added by the TCL sample conditioning system. The 499ACL-02 total chlorine sensor has a temperature rating of 32 to 122°F, a pressure rating of 0 to 65 psig and a standard 25ft cable. Wetted parts are gold, Noryl (PPO), Viton, EPDM and silicone.

Rosemount Analytical 499ACL-03 Monochloramine Sensor

The Model 499ACL-03 is intended for the determination of monochloramine in drinking water and wastewater. The linear range is 0 to 15 ppm(mg/L), 2% linearity and the accuracy depends on the accuracy of the laboratory method used to calibrate the sensor. The response time is less than 30 seconds to 90% of the final reading (o to 2 ppm) 25°C. The Model 499ACL-03 has a temperature range of 32 to 122°F and a 25 ft cable.

 

 

Applications:

 

High accuracy Rosemount Analytical 499 series / measurement analysis instruments 0

499ADO Dissolved Oxygen Sensor

The 499ADO is a membrane-covered amperometric sensor. It is intended primarily for the determination of dissolved oxygen in wastewater aeration basins.

High accuracy Rosemount Analytical 499 series / measurement analysis instruments 1

499AOZ Dissolved Ozone Sensor

The 499AOZ is a membrane-covered amperometric sensor. It is used in drinking water filter plants, fruit and vegetable packing facilities, bottling plants, and pharmaceutical manufacturing facilities

 

High accuracy Rosemount Analytical 499 series / measurement analysis instruments 0

499ATrDO Trace Dissolved Oxygen Sensor

The 499ATRDO sensor is a membrane-covered amperometric sensor. It is primarily used to measure trace oxygen levels in deaerated boiler feedwater in steam electric power plants.

High accuracy Rosemount Analytical 499 series / measurement analysis instruments 3

Bx438 Dissolved Oxygen Sensor for Food and Beverage

The BX438 sensor is a membrane-covered amperometric sensor. It is specially designed for measuring dissolved oxygen in carbonated beverages, like beer and soft drinks

High accuracy Rosemount Analytical 499 series / measurement analysis instruments 4

Gx448 Rebuildable Steam Sterilizable Dissolved Oxygen Sensor

The GX448 sensor is a steam-sterilizable membrane-covered amperometric sensor for the pharmaceutical industry. It has a G 1-1/4 process connection

High accuracy Rosemount Analytical 499 series / measurement analysis instruments 5

Hx438 Rebuildable Steam Sterilizable DO Sensor

The HX448 is a steam-sterilizable membrane-covered amperometric sensor for the pharmaceutical industry. It has a PG 13.5 process connection

High accuracy Rosemount Analytical 499 series / measurement analysis instruments 6

Oxygen Sensor Mounting Accessories

The BB-11 Floating Ball System and the HRMS HandRail Mounting Systems can be used with both the Dissolved Oxygen Sensor 499ADO and the RDO

High accuracy Rosemount Analytical 499 series / measurement analysis instruments 7

RDO® Optical Dissolved Oxygen System

The RDO® sensor and analyzer is intended for the determination of dissolved oxygen in water. It is ideal for use in wastewater aeration basins and ponds.

 

 

Specifications:

 

Model 499AOZ

Range: 0 to 3 ppm (mg/L) as O3.
Wetted Parts: Polysulfone, Viton1, Teflon2, silicone
Cathode: gold (not normally wetted)
Accuracy: Accuracy depends on the accuracy of the chemical test used to calibrate the sensor.
Linearity: ±5% of reading or ±3 ppb (whichever is greater) at 25°C
Repeatability: ±2% of reading at constant temperature
Response time: 30 sec to 90% of final reading at 25°C
Pressure: 0 to 65 psig (101 to 549 kPa abs)
Temperature (Operating): 32 to 122°F (0 to 50°C)
Membrane Permeability Correction: Defined between 41 and 95°F (5 and 35°F)
Sample Flow:
Flow through 1-5 gpm (3.8 to 19 L/min)
Open channel 1 ft/sec (0.3 m/sec)
Low flow cell 2 to 5 gph (7.6 to 19 L/hr)
Process Connection: 1 inch MNPT
Electrolyte Volume: 25 mL (approx.)
Electrolyte Life: 3 months (approx.); for best results, replace electrolyte monthly
Cable Length (standard integral cable): 25 ft (7.6 m)
Cable Length (maximum): 300 ft (91 m)

Full specifications at http://www2.emersonprocess.com/siteadmincenter/PM%20Rosemount%20Analytical%20Documents/Liq_ProdData_71-499AOZ.pdf


Model 499ADO

Range: 0 to 20 ppm (mg/L) as O2. For measurements
at the ppb level choose Model 499A TrDO.
Wetted Parts: Noryl1, Viton2, EPDM, Teflon3, (TFE)
silicone
Cathode: gold (not normally wetted)
Accuracy: ±0.2 ppm at 25°C
Repeatability: ±0.05 ppm at 25°C
Response time: 25 sec to 63% of final reading at 25°C
Pressure: 0 to 65 psig (0 to 549 kPa abs)
Temperature: 32 to 122°F (0 to 50°C)
Sample Flow:
Flow through 1-5 gpm (3.8 to 19 L/min)
Open channel 1 ft/sec (0.3 m/sec)
Low flow cell 2 to 5 gph (7.6 to 19 L/hr)
Process Connection: 1 inch MNPT
Electrolyte Volume: 25 mL (approx.)
Electrolyte Life: 4 to 6 months (approx.)
Cable Length (standard integral cable): 25 ft (7.6 m)
Cable Length (maximum): 300 ft (91 m)

Full specifications at
http://www2.emersonprocess.com/siteadmincenter/PM%20Rosemount%20Analytical%20Documents/Liq_ProdData_71-499ADO.pdf


Model 499ATrDO

Pressure: 0 to 65 psig (101 to 549 kPa abs)
Temperature: 32-122°F (0-50°C); membrane permeability correction defined between 41 and 113°F (5 & 45°C)
Wetted Materials: Noryl2, Viton3, Teflon4 (TFE), silicone
Cathode: gold (not normally wetted)
Process Connection: 1 inch MNPT
Electrolyte Volume: 25 mL (approx.)
Electrolyte Life: 4 to 6 months (approx.)
Sensor Life: 2 years (approx.)
Temperature Sensor: Pt 100 RTD (Type B)
Sample Flow: 1.6-6.3 gph (100-400 mL/min.) recommended.
Cable Length (standard integral cable): 25 ft (7.6 m)
Cable Length (maximum): 300 ft (91 m)

 

High accuracy Rosemount Analytical 499 series / measurement analysis instruments 8

 

Competitive Advantage:

 

RUGGED CONSTRUCTION

EASILY REPLACEABLE MEMBRANE; no special tools required.

AUTOMATIC COMPENSATION for changes in membrane permeability with temperature.

AUTOMATIC PRESSURE EQUALIZATION maintains correct membrane tension.

VARIOPOL (VP) CONNECTOR OPTION allows the sensor to be replaced without running new cable.

QUICK START UP. Self-depleting design means rapid consumption of internal oxygen. Comedown time following maintenance and calibration is fast.

 

Contact Details
Beijing Water Meter Co.,Ltd.

Contact Person: Miss.

Tel: 10-65569770

Fax: 86-10-8563-2312

Send your inquiry directly to us (0 / 3000)