Home ProductsRemote Reading Water Meter

35kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable

China Beijing Water Meter Co.,Ltd. certification
China Beijing Water Meter Co.,Ltd. certification
Cooperation is very satisfactory and the Company of the past few years, we are very willing to continue long-term cooperation.

—— Dean

The company considerate after-sales service ,And try their best to meet the requirement of customers. We will be a long-term cooperation.

—— Albert

Easy to talk with, very professional and fast service, the quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

I'm Online Chat Now

35kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable

35kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable
35kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable

Large Image :  35kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable

Product Details:
Place of Origin: Hebei, China(Mainland)
Brand Name: Xin Baofeng
Payment & Shipping Terms:
Minimum Order Quantity: 500 Meter/MetersTrial Order
Price: Negotiable
Packaging Details: drum
Delivery Time: Negotiable
Payment Terms: L/C,T/T
Detailed Product Description
High Light:

Medium Voltage Wire

,

underground electrical cable

1.Product standard
GB12706-91, GB/T18380.3-2001(IEC502  IEC332-3)


2.specifications and names
 

Type

Designation

Copper conductor

Aluminium conductor

ZRYJV

ZRYJLV

XLPE insulated and PVC sheathed fire retardant power cable

ZRYJV22

ZRYJLV22

XLPE insulated, steel tape armored and PVC sheathed fire retardant  power cable

ZRYJV32

ZRYJLV32

XLPE insulated, steel wire armored and PVC sheathed fire retardant  power cable.

ZRYJV42

ZRYJLV42

XLPE insulated, Crudewire armored and PVC sheathed fire retardant  power cable.

ZRVV

ZRVLV

PVC insulated, PVC sheathed fire retardant  power cable.

ZRVV22

ZRVLV22

PVC insulated, steel wire armored andPVC sheathed fire retardant  power cable.

ZRVV32

ZRVLV32

PVC insulated, steel wire armored and PVC sheathed fire retardant  power cable

ZRVV42

ZRVLV42

PVC insulated, Crudewire armored and PVC sheathed fire retardant  power cable.

3.Operating characteristics

1.(U0/U)0.6/1KV, 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 18/20KV, 21/35 KV, 26/35KV.

     The rated voltage(U0/U)0.6/1KV, 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 18/20KV, 21/35 KV, 26/35KV.

2. Max. permissible continuous operating temperatures of conductor not exceed 90°C, Max. short-circuit temperature of conductor shall not exceed 250°C. (5s Max. duration)

3.The ambient temperature under installation shall not below 0°C, the Min. bending radius: not less than 8 times for the cable of external diameter no more than 40mm; not less than 16 times for the others.

4.Test voltage of cable

Rated Voltage KV

0.6

1.8

3.6

6

8.7

12

18

21

26

Test voltage KV

3.5

6.5

12.5

21

30.5

42

63

73.5

91

5.Combustible and caustic property of cable

Item of test

Unit

Performance

Density of smoke test

Min. light transmittance

%

60

Causticity of test

Min. PH value

Max. electric conductibility

μS/mm

4.3

10

 Combustion test of bundled cable

grade of test

Time of supply fire

Total volume of combustible material per meter

Length affected by combustion

Min

l/m

m

A

40

7

B

40

3.5

C

20

1.5

<2.5

 6.Engine physics performance of insulation and sheath

Test item

Unit

Performance

Insulation

Sheath

Before ageing test

 

 

 

Min. tensile force

N/mm2

12.2

9

Min. elongation of rupture

%

200

125

After aged by oven

 

 

 

Temperature

°C

135±3

100±2

Duration

h

168

168

Max. rate of change of tensile strength

%

±25

 

Min. tensile strength

N/mm2

 

9

Max. rate of change of elongation at break

%

±20

 

Min. elongation at break

%

 

110

Test for thermal extension

 

 

 

Air temperature

°C

200±3

 

Loading time

Min

15

 

Mechanical tensile force

N/mm2

0.2

 

Max. elongation when loading

%

175

 

Maximum permanent deformation after cool

%

15

 

 Delivery lengths

The single length of cable is not less 100m, shortage length more than 20m may be delivered, but not exceed 10% of the total length, delivered special requirement to be discussed between the supplier and the buyer, the tolerance of length shall not exceed in ±0.5%.

35kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable 0

35kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable 1

35kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable 235kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable 3

35kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable 435kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable 535kv and Below Plastic Insulated Combustion Retarded Electric Middle Voltage Power Cable 6

 

Contact Details
Beijing Water Meter Co.,Ltd.

Contact Person: Miss.

Tel: 10-65569770

Fax: 86-10-8563-2312

Send your inquiry directly to us (0 / 3000)