Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding

Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding
Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding

Large Image :  Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding

Product Details:
Place of Origin: Jiangsu
Brand Name: BTW
Certification: KEMA,SGS
Model Number: SFP,SFPZ,OSFPS,SFPS,SFPSZ
Payment & Shipping Terms:
Minimum Order Quantity: 1 SET
Price: 200000-1000000 USD
Packaging Details: Fumigation wooden case
Delivery Time: 60-120 days
Payment Terms: L/C,T/T
Supply Ability: 30 SETS/mon
Detailed Product Description
Features: Low Loss, Low Noise Rated Voltage: 110kV
Cooling Type: Oil Immersed Frequency: 50HZ / 60HZ
Name: Phase Shifting Transformer Phase: Three-phase
High Light:

phase shift transformer

,

3 phase power transformer

Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding

 

 

Quick Detail:

 

1.Low loss, low noise

2.Low partial discharge

3.High quality, efficiency

4.Safe use

5.Power transformer

 

 

Description:

 

Our company provide 110kV and below oil-immersed power transformer ,with capacity of 120 MVA and below. The transformer is based upon world-wide advanced technology and also incorporates the experiences of internationally leading transformer companies as well as our own long-term experiences. Low loss, low partial discharge and high short circuit withstand capability series transformers are achieved through innovation and optimization. Our transformer conform entirely with latest national standard GB1094.1~2-1996, GB1094.3-2003, GB1094.5-2003 and international standard IEC-76. Outstanding features as follows:

1. Low loss, low noise

The core laminations are composed of imported high quality grain-oriented cold-rolled silicon steel sheets with chamfered joints and the joints are step-lapped with 5 steps, thus ensuring low loss and low noise. The inside of the tank is lined with magnetic and copper shields, measures have been take for metallic structural pares located in high magnetic field, to deduce stray loss and thereby the total load loss, and to relieve local overhearing.

2. Safe and reliable service

Reliability is the everlasting objective of our company, partial discharge of finished products are constantly kept below 100pC, ensuring that the transformers can be operated under long service voltage and occasional over-voltage without trouble. Low current density in winding conductor and appropriate cooling arrangement ensure that the winding temperature rise and top oil temperature rise are lower than that specified in the national standard by more than 5K and that the mechanical stress in winding conductor during short circuit does not exceed certain safe limit. Together with technological procedures during manufacture and other means to elevate mechanical strength, transformers can withstand server short circuit in all case during service.

3. Easy erection and maintenance

To minimize erection work at sit, transformers are so fabricated that lifting the active part out of the tank for inspection after arrival at sit is not mandatory. Beside, all components to be mounted on the transformer at site have been preassembled before dispatch, and all secondary wirings have been laid down into conduits on the transformer and connected to the terminals in the control cabinet or terminal box.

4. Careful fabrication

Vertical winding machines with tension device are used for winding, so that the windings can be wound more tightly and therefore mechanically strength as a whole. All insulation parts subjected to mechanical stress during short circuit, such as spacers in windings are made with T4 demystified pressboard to deduce shrinkage. Drying process for the windings are carried out twice, once for ht individual winding, and again for the assembled phase block.  After core and coil assembly, an additional vapor phase drying (VPD) is once more carried out to ensure that all insulation parts are thoroughly dried and no further shrinkage is possible to occur during service. All the high voltage terminals and nearby metallic structural parts are rounded up to prevent partial discharge. High voltage bushing terminals are contained with turrets, and kept concentric with the turret. All the leads are properly crimped and metallized to be rounded up. VPD process insures that the moisture content within the transformer is kept at a very low level, and the core and coil assembly is once more cleaned by condensed vapor flowing down the surfaces. The fabricated tanks are relived from welding stress and shot-blasted integrally, so as to be free form oil leakage trouble and to give the tank a clean, pleasant looking appearance.

 

220kV class high efficient and environment protective power transformer is based upon advanced technologies introduced from abroad and the successful experiences of leading manufacturers both domestic and abroad. It conforms entirely with up-to-date National Standard GB1094.1~2-1996,GB1094.3-2003,GB1094.5-2003 and International Standard IEC76 commended by international electrical engineering committee, and are proud of the following outstanding features:

1. Low loss, and significantly energy-saving. The average no-load loss is 35% lower than prescribed by National Standard GB/T 6451-2008.

2. The core laminations are made up from high-quality cold-rolled grain-oriented silicon steel sheets with chamfered joints and without punched holes, and are stacked without the upper yoke sheets in place, so that they are effectively improved no-load upper together with lower frame.

3. Zigzag directed flow of oil are provided within the windings, so that all parts of the windings can be cooled more evenly.

4. The regulating winding is a separate winding which apart from the high voltage main winding. In this way, total ampere-turn balance between windings ; and the axial electrodynamics force during short circuit can be  reduced, thus upgrading the short circuit withstand capability of the transformer as a whole.

5. The windings of one phase are assembled into an integral phase block before placing into the core.

6. The winding manufacture, winding assembly core and winding assembly work are all proceed in totally closed clean department.

7. Core frames in the form of a flat plate are used for clamping the core, and are joined together by side beams. The core and coil assembly is fixed in the tank, being positioned against the tank at six sides rigidly, so that there can be no displacement of the assembly due to impacts during transport.

8. Transformer tanks are fabricated with steel plates wide enough so that there are no weld joints on each surface. The steel plates for tank walls are pressed into corrugated shape to increase mechanical strength and to reduce noise due to vibration of the tank wall.

9. Diaphragm membrane is provided within the conservator, preventing direct contact of oil with air, protecting the oil from aging, thereby prolonging the service life of oil. Magnetic oil-level gauge reflects correctly the oil level in conservator. Flat plate-type radiator can effectively cool down the transformer.

10. Reliably sealed, and fine machined for sealed surface. Used double gasket grooves in their jointing surface and kept tight with high quality gasket material. If required by the customer, the upper and lower part of the tank can also be welded  tight.

11. High quality paint is applied as surface finish of the tank and exposed steel parts, after shot-blasting and pretreatment, thus ensuring a durable life and glossy surface.

12. Quality assurance rules are also observed for all insulating parts, from raw material to final assembly. Strict regulations are observed for drying, wrapping and storage, preventing the absorption of moisture, swelling, and deformation.

13. Main components

Because of good relationship and long-term co-corporation with all well-known sub-suppliers, we can meet the requirements of customers with whatever types of components they wish to have.

 

 

Applications:

 

Applied in residential buildings, business center, shopping center, small factories and so on.

 

 

Specifications:

 

Technical Data Table of Natural Air Cooling Three-phase Two-winding

Off-circuit Tap Changing Power Transformers with Low-loss and Low-noise

 

Type

Rated Voltage (kV)

Connection Symbol

 

No-load Loss

(KW)

 

Load Loss (KW)

 

No-load current

Short-circuit Impedance (%)

 Weight (t)

Dimensions (mm)

(mm)

HL

Track Spacing (mm)

 

Body

 

Oil

 

Total

 

Transport

 

L

 

W

 

H

S9-6300/110

H.V.:

110±2X2.5%

121±2X2.5%

 

L.V.:

6.3; 6.6; 10.5; 11

YNd11

7.5

36.9

0.63

10.5

7.6

7.6

23.0

18.5

5300

4680

4270

5200

1435

S9-8000/110

9.00

45.0

0.60

10.2

8.2

25.9

21.4

5540

4730

4420

5400

1435

S9-10000/110

10.50

53.1

0.56

12.5

9.3

30.2

23.8

5720

4830

4530

5700

1435

S9-12500/110

12.38

63.0

0.53

14.6

10.0

34.2

28.0

5780

4820

4630

5900

1435

S9-16000/110

15.00

77.4

0.49

16.7

11.1

38.2

30.3

6100

4850

4770

6200

2000

S9-20000/110

17.78

93.6

0.46

18.8

12.3

43.4

35.3

6190

5090

4780

6300

2000

S9-25000/110

21.00

110.7

0.42

23.2

12.6

48.1

37.3

6320

5310

4960

6700

2000

S9-31500/110

24.98

133.2

0.39

25.8

14.4

54.8

42.9

6360

5350

5020

6900

2000

S9-40000/110

29.85

156.6

0.35

31.0

16.3

63.6

48.7

6480

5400

5220

7200

2000

S9-50000/110

35.25

194.4

0.32

35.8

18.0

72.9

56.7

6640

5490

5260

7400

2000

S9-63000/110

41.85

234.0

0.28

39.6

19.8

84.3

64.4

6740

5510

5540

7900

2000

S9-90000/110

54.60

306.0

0.25

53.6

24.8

105.0

77.6

6880

5560

5780

8200

2000

 

A . Transformers application:

 

Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding 0

Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding 1

 

B . Production process:

 

Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding 2

 

C . Production Equipments:

 

Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding 3

 

D . Packing and Delivery Processing:

 

Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding 4

 

E . Quality Certificates:

 

Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding 5


Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding 6

 

F . Team Work:

 

Low Loss 110kv Oil Immersed Power Transformer For Building With Two-Winding 7

 

G . FAQ About Transformers:

 

Q: 1. Are transformers apply with Internation Standrad?

A: Yes, all our product are strictly apply with IEC,IS,ANSI,GB or any other special requirements as customers.

 

Q: 2. What is the lead time?

 A:Generally for one lot transformers within 60-90 days.

 

Q: 3. How do transformers been shipped?

A: Transformers always been deliveried by ship,train or truck for oversea.Which with main active body in bulk and accessories in wooden cases.

 

Q: 4. What kind of internation certificates do you have?

A: We have authoried KEMA,ISO and SGS.

 

Q: 5. What is your production ability for last year?

A: Last year our production ability reach 50 million KVA,and increased every year.

 

Q: 6. Do you offer guarantee for the products?  

A: Yes, we offer at least one year guarantee for all of our transformers.

 

Q: 8. Do you accept FAT(Factory Acceptance Test)?

A: Yes, it’s available.Welcomed.We are responsible for each set transformer’s testing.

 

Q: 9. Do you assign engineer for after-sale service?

A: Yes,for our products,we all show after-sale guide installation and questions inquiry.

 

 

Competitive Advantage:

 

1.Low loss, low noise

2.Low partial discharge

3.High quality, efficiency

4.Safe use

5.Power transformer

 