Home ProductsWaste Water Flow Meters

Electromagnetic Flow Meter for Waste Water Plants With Reasonable price

China Beijing Water Meter Co.,Ltd. certification
China Beijing Water Meter Co.,Ltd. certification
Cooperation is very satisfactory and the Company of the past few years, we are very willing to continue long-term cooperation.

—— Dean

The company considerate after-sales service ,And try their best to meet the requirement of customers. We will be a long-term cooperation.

—— Albert

Easy to talk with, very professional and fast service, the quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

I'm Online Chat Now

Electromagnetic Flow Meter for Waste Water Plants With Reasonable price

Electromagnetic Flow Meter for Waste Water Plants With Reasonable price
Electromagnetic Flow Meter for Waste Water Plants With Reasonable price

Large Image :  Electromagnetic Flow Meter for Waste Water Plants With Reasonable price

Product Details:
Place of Origin: China
Brand Name: AUTO
Certification: CE,ISO9001:2008
Model Number: WFD
Power supply: 24V DC,220V AC,battery
Pressure: 1.6-4.0MPa
temperature: -20 to 350C
Output signal: 4-20mA,LCD Display,pulse output
Measure range: DN10-DN2000
Skype: summer.cap39
Measuring medium: water and other liquid
Payment & Shipping Terms:
Minimum Order Quantity: 1unit
Price: USD197-300/pc
Packaging Details: Carton
Delivery Time: 3-7days after confirm orer
Payment Terms: T/T,L/C,Paypal
Supply Ability: 1500unit/month
Detailed Product Description

   Electromagnetic Flow Meter for Waste Water Plants With Reasonable price

       Electromagnetic Flow Meter for Waste Water Plants With Reasonable price 0

 

Product description:

WFD electromagnetic flowmeter, composed of sensor and converter, works based on Faraday's law of

electromagnetic induction. It is used to measure electricalconductivity of liquid or solid. Generally, the electrical

conductivity should be over 5uS/cm (electrical conductivity of tap water, raw water is about 100-500uS/cm. It

can also be used to measure various mediums like acid, alkali, saline solution, paper pulp, ore pulp

and so on, but these mediums can't contain a lot of magnetic materials and bubbles.

 

Applications of Magnetic Flow Meter

  • Water Treatment
  • Pump Testing
  • Paper & Pulp
  • Effluent Treatment Plants
  • Waste Water & Sewerage
  • Food & Diary Processing
  • Chemical Process Plants

 

Technical Parameters:

 

Technical Performance Parameters

  Caliver 

DN10~DN3000mm

  Nominal Pressure

0.6~1.6MPa(special pressure can be made to)

  Accuracy

 ±0.5%,±0.3%or±0.2% are selectable

  Liner material

PTFE,PFA,F46,Neoprene,Polyurethane

  Electrode Type

General type ,scraper type and replaceable type

  Electrode material

Stainless steel SUS316,Hastelloy C,Titanium,

Tantalum Platinumiridium,

Stainless steel covered with tungsten carbide

Mediem temperature

Integrate type

 -20°C~+60°C

Remote type

 Neoprene & Polyurethane Liner

    -10°C~+80°C

 PTFE Liner /PFA Liner /F46 Liner

            -10°C~+160°C

  Ambient Temperature

-25°C ~+ 60°C

  Ambient Humidity

5~100%RH(relative humidity)

  Medium Electrical conductivity

≥20μ s/cm

  Measuring Range

1500:1,flow rate<15m/s

  Structure type 

Integral type,remote type,submersible type,ex-proof type

  Protection Class

IP65,IP68(optional)

  Ex-proof Mark

ExmdⅡT4

  Product Standard

JB/T 9248-1999 Electormagnetic Flowmeter

Main Performance of the electrode materials:

 

 

Main performances of the electrode materials

  Electrode material

  Applications

   SUS316

 Applicable in water,sewage and corrosive mediums.

Widely used in industries of petrol,chemistry,carbamide,etc

  Stainless steel  

covered with tungsten

 carbide

  Applicable in mediums of no corrosive and low abrasion.

  Hastelloy B(HB)

 Having strong resistance to hydrochloric acid of any consistance

 which is below bioling piont.Also resistable against vitriol,phosphate,

 hydrofluoricacid,organic acid etc which are oxidable acid,alkali and non-oxidable salt.

  Hastelloy C(HC)

 Be resistant to oxidable acid such as nitric acid,mixed acid

 as well as oxidable salt such as Fe+++,Cu++aStnd sea water

  Titanium

 Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid

 (including fuming nitric acid),organic acid,alkali etc.

 Not resistant to a pure reducing acid(such as sulphuric acid,hydrochloric

 acid   corrosion.

 But if acid contains antioxidant is greatly reduce corrosion.

  Tantalum

 Having strong resistance to corrosive mediums that is similar with glass

 Almost is applicable to all chemical mediums.

 Except for hydrofluoric acid,oleum and alkali.

  Platinum-iridium

 Almost be applicable in all chemical mediums except for ammonium salt.

         Electromagnetic Flow Meter for Waste Water Plants With Reasonable price 1

 

 

Product details:

               Electromagnetic Flow Meter for Waste Water Plants With Reasonable price 2

            Electromagnetic Flow Meter for Waste Water Plants With Reasonable price 3

Order sheet:

 

Name

Specification code

Explanation

Instrument type

 

Intelligent electromagnetic flow meter

Diameter code

xxx

For example:100 represents DN100

Electrode form

1

Standard stationary type

 

 

 

 

Electrode material

0

Stainless steel(316L)

1

Platinum Pt

2

Hastelloy B(HB)

3

Tantalum Ta

4

Titanium Ti

5

Hastelloy C(HC)

 

 

 

Lining material

3

Chloroprene rubber

4

Polyurethane rubber

5

F4(PTFE) polytetrafluoroethylene

6

F46(FEP)polyperfluoroethylene-propylene

 

 

 

Rated pressure(MPa)

4.0

DN10-80

1.6

DN100-150

1.0

DN200-1000

0.6

DN1100-2000

0.25

DN2200

 

Operating temperature

E

<80℃

H

<120℃

Grounding

&nb

Contact Details
Beijing Water Meter Co.,Ltd.

Contact Person: Miss.

Tel: 10-65569770

Fax: 86-10-8563-2312

Send your inquiry directly to us (0 / 3000)