Product Details:
Payment & Shipping Terms:
|
Suitable Pipe Diameter: | DN15-6000mm | Principle: | Transit-time Ultrasonic Flowmeter |
---|---|---|---|
Pipe Material: | Steel, Stainless Steel, Cast Iron, Copper, Cement Pipe, PVC, Aluminum, Glass Steel Product, Liner Is Allowed. | Wall Mounted: | TUF-2000SW |
Panel Mounted: | TUF-2000SS | Explosin-proof: | TUF-2000SD |
Type Of Liquid: | Water (hot Water, Chilled Water, City Water, Sea Water, Waste Water, Etc.); Sewage With Small Particle Content; Oil (crude Oil, Lubricating Oil, Diesel Oil, Fuel Oil, Etc.); Chemicals (alcohol, Acids, Etc.); Plant Effluent; Beverage, Liquid Food; Ultra-p | Display: | 2×20 Character LCD With Backlight, Support The Language Of Chinese, English And Italy Convertor Dimension:170*180*56cminese, English And Italy |
High Light: | ultrasonic flow meter,portable flow meter |
Fixed type ultrasonic flowmeter wall hanging digital flow meter TUF-2000S
Optional Main unit
According to different installation condition,there are three models separated ultrasonic flowmeter for selection:
Wall-mount | Panel-mount | Explosion-proof |
Wall mounted TUF-2000SW Indoor or instrument box installation Dimension:170*180*56mm Power supply:DC8~36V or AC85~264V | Panel mounted TUF-2000SS Instrument Cabinet installation Dimension:170*180*56mm Hole-opening dimension:156*76mm Power supply:DC8~36V or AC85~264V | Explosin-proof TUF-2000SD |
Optional Transducer
Clamp on Transducer | Clamp on sensor with the magnet, you can install the transducer very easily when |
Insertion Transducer | No need to cut off water, no pressure loss; |
Pipe | Need to cut off water, no pressure loss; |
[ Feature ]
High Accuracy
1%
Wide measuring range
Several types transducer for selection, pipe size from Dn15mm to Dn6000mm
High Reliability
Adopt low voltage, multi-pulse technology to improve accuracy, operation life and reliability.
Strong Anti-interference
Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high
voltage line etc.
Powerful Recording Function
Automatically record the following data:
1. The totalizer data of the last 512 days/128 months/10 years
2. The time and corresponding flow rate of the last 6 4 times of power on and off events
3. The working status of the last 32 days
Support Heat Measurement
Connect the temperature transducer ,can finish the heat/energy measurement
Support SD card Memory
Optional SD card
[ Main Feature ]
Item | Performance and Parameter | |
Convertor | Principle | transit-time ultrasonic flowmeter |
Accuracy | Flow: over 1%-2%(battery-powered supply over ±2% ),Heat: over ±2%,Repeatability: over 0.2% | |
Display | 2×20 character LCD with backlight, support the language of Chinese, English and Italy Convertor dimension:170*180*56cm | |
Operation | Support 16 key light touch keyboard and the Simulation keyboard software | |
Signal Output | 1 way 4~ 20mA output, electric resistance 0~ 1K,accuracy0. 1% | |
1 way OCT pulse output( Pulse width 6 ~ 1 0 0 0 ms,default is 2 0 0 ms) | ||
1 way Relay output | ||
Signal Input | 3 way 4~ 20mA input, accuracy 0. 1%,acquisition signal such as temperature, press and liquid level | |
Connect the temperature transducer Pt100, can finish the heat/energy measurement | ||
Data interface | Insulate RS485 serial interface, upgrade the flew meter software by computer, support the MODBUS, METER-BUS etc. | |
Other Function | Automatically remember the previous flew/energy data of 512 days, 128 months and 10 years | |
Automatically remember the previous flew/energy data of 512 days working condition and check it | ||
Automatically remember the previous 32 times power on/off time and flow rate | ||
|
|
|
Special Cable | Twisted-pair cable, generally, the length under 50 meters;Select the RS485 communication. The transmission distance can over 1000m. | |
Pipe Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed. |
Pipe Diameter | 15---6000mm | |
Straight length pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump. | |
Measuring Medium | Type of Liquid | Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, acids, etc.); Plant effluent; Beverage, liquid food; Ultra-pure liquids; Solvents and other liquids |
Temperature | Standard Transducer: -30--90℃; High-temperature transducer: -30--140℃ | |
Turbidity | No more than 10000ppm and less bubble | |
Flow rate | 0--±7 m/s | |
Working Environment | Temperature | Main Unit: -20--60℃ |
Flow transducer: -40--160℃; | ||
Humidity | Main Unit: 85% RH; Flow Transducer: Ip67 | |
Power Supply | DC 24V or AC 85-264V | |
Power Consumption | 1.5W |
Contact Person: Miss.
Tel: 10-65569770
Fax: 86-10-8563-2312
Portable Ultrasonic Flow Meter, High Reliability Waterproof Flowmeter TUF-2000F
High Accuracy Portable Flowmeter , Online Ultrasonic Flow Meter TUF-2000S
TUF-2000H Handheld Ultrasonic Flow Meter, Non-Intrusive Measuring Flowemeter
Automatic Read Residential Plastic Multi Jet Water Meter With PDA/ Fixed Network
Plastic Nylon Multi Jet Super Dry Cold Water Meter ISO4064 Class B
Brass Multi Jet Domestic Water Meter Hot With End Flange / BSP LXSR-50E
YSI Pro20 Dissolved Oxygen METER and Temperature Handheld 6050020
Single Jet Water Meter Dry Dial LXSC-15D For Resident, Remote Reading Water Meter
Resident Rotary Domestic Single Jet Water Meter Anti Magnetic For Hot Water