| Product Details: 
 Payment & Shipping Terms: 
 | 
| Highlight: | gas mass flow meter,thermal mass flowmeter | ||
|---|---|---|---|
Flange Sensor Ultrasound Slurry Density Meter Tpd - S1c10dn100p10
1. Features and Benefits
• Ultrasonic measurement method, no radiation pollution, absolute security
• Ultrasonic emission energy automatically adjust to accommodate a variety of measuring ranges and different media
• Advanced circuit design and software algorithms to eliminate on-site interference, stable and accurate measurement
• Immersion sensors are mainly used in large diameter pipes, containers, ponds, rivers measurement occasions
• Flange and plug-in sensors used to measure the concentration of fluids in pipes
• Large-screen LCD display, can display trend lines
• Measurement units% or g / L can be selected in the field
• 4 ~ 20mA current output isolation
• Upper and lower limit alarm and fault alarm relay output
	
	2. Application
Beneficiation: milling, the second milling, first beneficiation, second beneficiation, tailings
Coal washing plant, sand, paper mill, power plant
3. Specifications
| Performance characteristics | |
| Measuring Range | 0.2% - 80% | 
| Resolution | 0.10% | 
| Accuracy | ±12.5%FS | 
| Calibration | Field or factory calibration | 
| Outputs | |
| Analog output | 4~20mA,max load 500Ω | 
| Relay output | Upper and lower hysteresis alarm relay output | 
| Relay capacity | 2A, 250VAC | 
| Digital interface | RS-485, Profibus DP, MODBUS | 
| Power supply | |
| AC Power Supply | 220VAC±10%, 50Hz | 
| DC Power Supply | 24 VDC ±10% | 
| Physical properties | |
| Transmitter dimension | 256*270*139mm | 
| Sensor type | Immersion, plug-in and flange | 
| Material | cast aluminium(transmitter) Stainless steel(sensor) | 
| Weight of transmitter | 1Kg | 
| Weight of sensor | 0.5Kg | 
| Sensor cable | Shielded cable 10meters (Other lengths can be described in the order) | 
| Environmental conditions | |
| Ingress protection | IP65(transmitter) IP68(sensor) | 
| Operating Temperature | 0 - 60 ° C | 
| Relative humidity | 0 -95% | 
| Operating Pressure | ≤7.5Bar | 
4. Ordering Information
Transmitter types
| 
 | signal output | power supply | ||
| TPD | code | meaning | code | meaning | 
| 
 | 10 | 4- 20mA | AC | 220VAC | 
| 
 | 11 | RS-485(MODBUS) | DC | 24VDC | 
| 
 | 12 | Profibus DP | 
 | |
Example: TPD10AC means output 4 – 20mA, alternating current 220V
Flange sensor types
| 
 | cable length | Pipe inner diameter | pressure rating | |||
| TPD–S1 | code | meaning | code | meaning | code | meaning | 
| 
 | C10 | 10meter cable | DN** | Inner diameter | P06 | 0.6Mpa | 
| 
 | CXX | Xxmeter cable | ( DN40-DN400) | P10 | 1.0Mpa | |
| 
 | 
 | 
 | Other diameters can be customized | P16 | 1.6Mpa | |
Example: TPD–S1C1ODN100P10 means flange sensor with 10meter cable, DN100 inner diameter and 1.6Mpa pressure.
Contact Person: Miss.
Tel: 10-65569770
Fax: 86-10-8563-2312
Portable Ultrasonic Flow Meter, High Reliability Waterproof Flowmeter TUF-2000F
High Accuracy Portable Flowmeter , Online Ultrasonic Flow Meter TUF-2000S
TUF-2000H Handheld Ultrasonic Flow Meter, Non-Intrusive Measuring Flowemeter
Automatic Read Residential Plastic Multi Jet Water Meter With PDA/ Fixed Network
Plastic Nylon Multi Jet Super Dry Cold Water Meter ISO4064 Class B
Brass Multi Jet Domestic Water Meter Hot With End Flange / BSP LXSR-50E
YSI Pro20 Dissolved Oxygen METER and Temperature Handheld 6050020
Single Jet Water Meter Dry Dial LXSC-15D For Resident, Remote Reading Water Meter
Resident Rotary Domestic Single Jet Water Meter Anti Magnetic For Hot Water