Product Details:
Payment & Shipping Terms:
|
High Light: | total suspended solids,total suspended solids |
---|
0 - 9999mg/L MLSS Analyzer, Suspended Solids Analyzer / Meter MLSS10AC
1. Application
Measure low, medium and high suspended solids concentrations using the multi-beam pulsed light method in municipal and industrial wastewater treatment process
• Sewage treatment plants
Inflow of wastewater, aeration tanks, returned sludge, primary sedimentation tanks, secondary sedimentation tank, thickening tank, sludge dewatering, etc.
• Water supply plants
Sedimentation tank
• Pulp & Paper
Pulp density
• Coal preparation plant
Sedimentation tanks, concentration tanks
• Power plant
Influent water treatment, Condensate, Boiler feed water, Cooling water, Wastewater
• Other industries:
Gush arenaceous liquid of PCB industry, marsh gas generate electricity( biogas power generation).
2. Features and Benefits
• Based on the innovative multi-beam light method for compensation of sensor soiling, the measurement is
not affected by contamination.
•High-quality 880nm optical and electronic assemblies eliminate interference from extraneous light sources.
• Digital sensor has good anti-interference performance and high stability, and the cable length is available in hundreds of meters.
• Connections between the sensor(s) and the transmitter are “plug and play”, and multi-channel transmitter operates either 1 or 2 sensors.
• Modbus RS485/RS232 or Profibus DP network connection for data transmission is Optional.
• The menu is available in Chinese or English.
• 3 Relays with programmable hysteresis provide high-limit alarm, low-limit alarm or timer.
• A built-in data logger with the capacity to store data for up to 10 years collects measurement data at user selectable intervals.
3. Specifications
Performance characteristics |
|
Measuring Range |
Activated sludge: 0~25g/L,0~9999mg/L, 0~400g/L (depends on the medium) |
Measurement Units |
g/L,,mg/L,ppm,% (optional) |
Resolution |
0.01g/L, 1mg/L, 1ppm, 0.01% |
Accuracy |
±1%FS (depends on the medium and homogeneity) |
Repeatability |
1% |
Response time |
Less than1 second (adjustable) |
Calibration |
Factory calibrated, also can be calibrated by customer on site |
Display |
LCD displays data including date, time, measurement value, trendline, etc., English menu |
Data storage |
Automatic Data Storage for up to 10 years, power-off data protection |
Outputs |
|
Analog Outputs |
0/4-20 mA output( maximum load 800 ohms), optional selection of 3.8mA or 21mA(under the condition of malfunction) |
Relay Outputs |
3 Relays with programmable hysteresis, alarm or timer function optional |
Relay Capacity |
2A, 250VAC |
Digital Communication |
MODBUS RS232/RS485,Profibus DP is optional |
Power supply |
|
AC power supply |
85~265 VAC, 50Hz/60Hz |
DC power supply |
24 VDC ±10% |
Physical parameters |
|
Dimension of Transmitter |
270×205×100mm(W×H×D) (10.6*8*3.9 in.) |
Dimension of Sensor |
Φ45×112mm (1.8*4.4 in.) |
Materials |
--Transmitter: PC --Sensor: 316L stainless steel |
Process Connection of Sensor |
1 inch cone male thread |
Pipe Installation Fitting |
for pipes from DN 65, < 6 bar (87 psi) |
Environmental conditions |
|
Ingress Protection |
--IP66 (transmitter) --IP68 (Sensor) |
Operating Temperature |
--Transmitter: -20~60℃ --Sensor: 0~60℃ |
Operating Pressure |
≤6Bar |
Air Cleaning |
0.7~3Bar |
4. Ordering Information
Ordering Information |
||||||
Transmitter Selection |
||||||
|
Channel number |
Signal output |
Power version |
|||
MLSS |
|
|
|
|||
|
code |
meaning |
code |
meaning |
code |
meaning |
|
1 |
Single channel |
0 |
4~20mA |
AC |
220VAC |
|
2 |
Dual channel |
1 |
RS 485(Modbus) |
DC |
24VDC |
|
|
|
2 |
RS 232(Modbus) |
|
|
|
|
|
3 |
Profibus DP |
|
|
Example: MLSS10AC, single channel transmitter of suspended solids concentration analyzer, output 4~20mA, 220V AC Power Supply. |
||||||
Sensor Selection |
||||||
|
Install mode |
Cable length |
||||
MLSS-S |
|
|
||||
|
code |
meaning |
code |
Meaning |
||
|
0 |
Immersion installation |
C10 |
10m cable |
||
|
1 |
Insertion installation |
CXX |
XXm cable |
||
Example: MLSS-S0C10, a suspended solids concentration sensor, immersion-typed install , with 10m cable. |
(3) Accessories
FA0000: Immersion mounting bracket, stainless steel
FA0001: Immersion mounting bracket, PVC
FA0010: Insertion mounting bracket, stainless steel, with DN50 stainless steel cut-off ball valve
FA0020: Stainless steel floating ball mounting bracket
FA0021: PVC floating-board mounting bracket
FA0900: Stainless steel adapter
FA0901: PVC adapter
FA0800: Instrument protective housing, stainless steel
FA0810: Instrument protective housing, stainless steel, with heater unit
FC0000: Automatic air cleaning accessories
Contact Person: Miss.
Tel: 10-65569770
Fax: 86-10-8563-2312
Portable Ultrasonic Flow Meter, High Reliability Waterproof Flowmeter TUF-2000F
High Accuracy Portable Flowmeter , Online Ultrasonic Flow Meter TUF-2000S
TUF-2000H Handheld Ultrasonic Flow Meter, Non-Intrusive Measuring Flowemeter
Automatic Read Residential Plastic Multi Jet Water Meter With PDA/ Fixed Network
Plastic Nylon Multi Jet Super Dry Cold Water Meter ISO4064 Class B
Brass Multi Jet Domestic Water Meter Hot With End Flange / BSP LXSR-50E
YSI Pro20 Dissolved Oxygen METER and Temperature Handheld 6050020
Single Jet Water Meter Dry Dial LXSC-15D For Resident, Remote Reading Water Meter
Resident Rotary Domestic Single Jet Water Meter Anti Magnetic For Hot Water