Product Details:
Payment & Shipping Terms:
|
CAS: | 77-86-1 | Assay: | 99% |
---|---|---|---|
Formula: | C4H11NO3 | Appearance: | White Crystalline Powder |
MP: | 168-171℃ | Storage: | Room Temperature |
HS: | 2922199090 | ||
Highlight: | biology buffer,HEPES |
Tris hydroxymethyl aminomethane Biological Buffers CAS NO 77-86-1 99%
Quick Detail:
Name |
Tris |
Appearance |
White crystalline powder |
Assay: |
99.9% |
PH value (5% aq.) |
10-11.5 |
Water content |
0.13 |
Heavy metals, ppm |
≤5 |
Ultraviolet absorbance/280nm (40% aq.) |
0.069 |
Ultraviolet absorbance/400nm (40% aq.) |
0.018 |
Description:
> Formula:: C4H11NO3
> Weight:: 121.135
> Appearance: White crystalline powder
> MP/BP:168-171℃
> Storage: room temperature
> HS:2922199090
> Safety Description: S26 S36
> Danger Description: R36/37/38
> Danger Symbol: Xi
Applications:
3. Note:
Tris buffer is temperature sensitive and should be used at the temperature at which it was originally
pH to avoid inaccuracy, in addition, Tris inhibits a number of enzymes, and therefore it should be
used with care when studying proteins.
Specifications
Assay |
99.9% |
MP |
168-171℃ |
Solubility (40% aq.) |
Clear, colorless solution |
Heavy metals, ppm |
≤5 |
Water content,% |
0.13 |
PH value (5% aq.) |
11.29 |
Iron ion, ppm |
≤1 |
Sulfate,ppm |
≤10 |
Chloride,ppm |
≤3 |
Ultraviolet absorbance/280nm (40% aq.) |
0.069 |
Ultraviolet absorbance/400nm (40% aq.) |
0.018 |
Shelf life |
Two years |
Synonyms:
1,1,1-tris(hydroxymethyl)-methanamin;1,1,1-tris(hydroxymethyl)-methylamin;1,1,1-tris(hydroxymethyl)methylamine;1,3-Propanediol,2-amino-2-(hydroxymethyl)-;2-amino-2-(hydroxymethyl)-3-propanediol;2-Amino-2-hydroxymethylpropanediol;2-Amino-2-methylol-1,3-propanediol;3-Propanediol,2-amino-2-(hydroxymethyl)-1;2-Amino-2-hydroxymethyl-1,3-propanediol;
TRIS; Tromethamine; Tromethane; tris(hydroxyme.)aminomethane; trizma base; Trometamol; tri(hydroxymethyl)methylamine; Tris(hydroxymethyl) methylamine Tris buffer 99.8+ %;
Trihydroxymethyl Aminomethane; Tris, Ultra Pure; Tris, Tissue Culture Tested Tris(hydroxymethyl)aminomethane, Tissue Culture Tested; Tris, Alcohol Free Tris(hydroxymethyl)aminomethane, Alcohol Free; Tris(hydroxymethyl)aminomethane, Ultra Pure, Molecular Biology Grade; Tris EDTA acetate buffer; THAM; Trimethanolaminomethane; Tri(hydroxymethyl)aminomethane; Tris(hydroxymethyl)aminomethane;
2-Amino-2-(hydroxymethyl)-1,3-propanediol; Tris hydroxyl methyl amino methane;
2-amino-2-(hydroxymethyl)propane-1,3-diol; 1,3-dihydroxy-2-(hydroxymethyl)propan-2-aminium; (methylamino)methanetriol; Tris(hydroxymethyl) aminomethane
Related categories:
Biochemistry;Reagents for Electrophoresis;Buffer;ACS Grade Buffers;Amino Alcohols;Biological Buffers;Buffers A to Z;Building Blocks;Chemical Synthesis;Organic Building Blocks;Oxygen Compounds
Related Products:56-40-6;10043-35-3;67-68-5;3483-12-3;1185-53-1;9002-93-1
The determination of PH
Weigh a certain amount of samples into test tube, add a certain amount of water, shake and dissolve,
determination of the pH used have been calibrated pH meter.
The determination of solubility
Weigh a certain amount of samples into test tube, add a certain amount of water, shake and dissolve,
observe the solution.
Determination of melting point
Instrument:Micro melting point apparatus WRS-2A, Melting point tubes
Determination of step:
Open switch, stable 20min.
First set the starting temperature than the melting point of the low 10 ℃, heating rate 2 ℃ / min.
The sample was grind as fine as possible and load in a clean, dry melting point pipe ,until the sample
was compressed into about 1cm high .When the actual temperature reaches the set temperature and
stabilized . Inserted into the capillary with the sample, the simultaneous determination of three.
The determination of KF
Use MA-1 intelligent Carle Fischer moisture tester to measure water content
Determination of iron content
Preparation of standard iron solution
Weigh ammonium iron(III) sulfate [FeNH4(SO4)2·12H2O] 0.863g .Placed in 1000mL volumetric flask,
add water to dissolveand add sulfuric acid 2.5mL.Diluted with water to the mark, shake, as the stock
solution.Before use, exact amount of stock solution 1mL, placed in 100mL flask, diluted with water to
the mark and shake.
Weigh 1g sample, placed in a crucible.Adding sodium carbonate 2g and mixed.Burning at 740 ℃,
the residue is dissolved in dilute hydrochloric acid 15ml , displacing 50mL Nessler colorimetric tube ,
add dilute hydrochloric acid 4mL and ammonium persulfate 50mg , Diluted with water to make into 35mL, add 30% ammonium thiocyanate solution 3mL, plus the amount of water diluted into 50mL, shaked.
If the color, take 1mL standard iron solution into 50mL Nessler colorimetric tube, add water to 25mL,4mL
dilute hydrochloric acid and 50mg ammonium persulfate , diluted with water to 35mL, then plus 30%
ammonium thiocyanate solution 3mL, plus the amount of water diluted into 50mL, shake comparisons.
Detection of heavy metals
The meaning of heavy metals of this act is under the specified experimental condition, which can
coloration effects with sodium sulfide or thioacetamide .The glasses of preparation or storage is not
allowed to contain lead.
5.8.1 Reagents
a) Lead dinitrate:1μg/mL
b) Sodium hydroxide :10%(m/v)
c) Sodium sulfide :10%(m/v)
5.8.2 Preparation of lead standard solution
Weigh lead dinitrate 0.1599g ,relocated to 1000mL volumetric flask, plus nitric acid 5mL and water
50mL, diluted with water to the mark , shake, as the stock solution.
5.8.3 Determination of step
Before use, the exact amount of stock solution 1mL, relocated to a 100ml volumetric flask, dilute with
water to the mark, shake, limit the use of the day .
Weigh sample 1g, after adding sodium hydroxide solution 5mL and 20mL of water to dissolve, set
Nessler colorimetric tube, add 5 drops of sodium sulfide , shake , compared the color with 5mL lead
standard solution after the same treatment, not deeper
The determination of UV absorbance
A certain amount of the sample was weighed to the nearest 0.0001g, into 10ml volumetric flask,
after constant volume with pure water, at a specific wavelength by 2cm cuvette was measured by
UV spectrophotometer.
Contact Person: Miss.
Tel: 10-65569770
Fax: 86-10-8563-2312
Portable Ultrasonic Flow Meter, High Reliability Waterproof Flowmeter TUF-2000F
High Accuracy Portable Flowmeter , Online Ultrasonic Flow Meter TUF-2000S
TUF-2000H Handheld Ultrasonic Flow Meter, Non-Intrusive Measuring Flowemeter
Automatic Read Residential Plastic Multi Jet Water Meter With PDA/ Fixed Network
Plastic Nylon Multi Jet Super Dry Cold Water Meter ISO4064 Class B
Brass Multi Jet Domestic Water Meter Hot With End Flange / BSP LXSR-50E
YSI Pro20 Dissolved Oxygen METER and Temperature Handheld 6050020
Single Jet Water Meter Dry Dial LXSC-15D For Resident, Remote Reading Water Meter
Resident Rotary Domestic Single Jet Water Meter Anti Magnetic For Hot Water