                     Product Details: 
						                        
 Payment & Shipping Terms: 
							
  | 
                            
| Highlight: | liquid flow meters,gas flow meter | 
			    	||
|---|---|---|---|
		
		
		Water Electromagnetic Flow Meters / Flowmeter TLD10B1YSAC Urethane Rubber Underlining DN10
		
		
		1. Application
•Water and wastewater treatment: Inlet pipeline, outlet pipeline, sludge pipeline, etc.
2. Features and Benefits
• The 4 electrode measuring system: Measuring electrode,reference electrode,empty pipe detection electrode;
• No activity parts blocking the flow in the measuring pipeline, and no pressure losing.
		• The measuring result has nothing with physical parameter, like fluid density, viscosity, temperature,
		 pressure, and electric conductivity (not less than 5μs/cm), etc.;
		• Two direction measuring system, built-in three calculators: direct aggregates, inverse aggregates, 
		and difference between direct and inverse aggregates. 
• Different lining and electrode material could be selected, has good corrosion resistance;
• Unique anti-interference filter circuit and arithmetic processor, output stably;
• Variety of output functions, and the width of output pulse is adjustable
• Grounding electrode, grounding rings, and lightning protection devices, ensure the safety.
• Measuring Range can be segmented set;
• LCD displays a plenty of information, including instantaneous flow and cumulative flow.
• Measurement system has ability of avoid vibration and electromagnetic interference.
• Support HART protocol communication and Profibus is Optional
3. Specifications
| 
					 Performance characteristics  | 
			|
| 
					 Nominal Diameter  | 
				
					 DN 10 ~ DN 3000  | 
			
| 
					 Flow rate Range  | 
				
					 0.2 ~ 10 m/s  | 
			
| 
					 Accuracy  | 
				
					 ±0.5% FS  | 
			
| 
					 Repeatability  | 
				
					 0.1 %  | 
			
| 
					 Calibration  | 
				
					 Factory calibrated  | 
			
| 
					 Display  | 
				
					 LCD  | 
			
| 
					 Damping Time  | 
				
					 0.5 ~ 60 sec. (can be increased second to )  | 
			
| 
					 Power-off Protection  | 
				
					 
						In case of power-off , parameter values will be saved in memory that hard to lose,   | 
			
| 
					 Outputs  | 
			|
| 
					 Analog Outputs  | 
				
					 4-20 mA output  | 
			
| 
					 Pulse  | 
				
					 3.6 ~ 3600000 pulse/hour, Pulse width: 0.5 ~ 500 ms  | 
			
| 
					 Digital Communication  | 
				
					 MODBUS RS232/RS485,Profibus DP is optional  | 
			
| 
					 Power supply  | 
			|
| 
					 AC Power Supply  | 
				
					 220 VAC±10%, 50Hz  | 
			
| 
					 DC Power Supply  | 
				
					 24 VDC ±10%  | 
			
| 
					 Physical parameters  | 
			|
| 
					 Material of Shell  | 
				
					 Aluminum alloy with acrylic resin coating  | 
			
| 
					 Optional material of electrode  | 
				
					 stainless steel; Hastelloy C  | 
			
| 
					 Optional material of Lining  | 
				
					 Neoprene, polyurethane, PTFE  | 
			
| 
					 Connection  | 
				
					 Flanged  | 
			
| 
					 Environmental conditions  | 
			|
| 
					 Ingress protection  | 
				
					 --IP65 (Transmitter of split meter) --IP68 (Sensor of separate meter) --IP67 (Integrative meter)  | 
			
| 
					 Operating Temperature  | 
				
					 -Transmitter: -10 ~ 40℃ --Sensor: -25 ~ 60℃  | 
			
| 
					 Humidity  | 
				
					 0~85%  | 
			
4. Ordering Information
| 
					 Ordering Information  | 
			||||||||||||||
| 
					 
  | 
				
					 Diameter of the pipe  | 
				
					 Material of lining  | 
				
					 Material of electrode  | 
				
					 Structure of the meter  | 
				
					 Signal output  | 
				
					 Power supply  | 
				
					 Pressure grade  | 
			|||||||
| 
					 TLD  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
			|||||||
| 
					 
  | 
				
					 Code  | 
				
					 Meaning  | 
				
					 Code  | 
				
					 Meaning  | 
				
					 Code  | 
				
					 Meaning  | 
				
					 Code  | 
				
					 Meaning  | 
				
					 Code  | 
				
					 Meaning  | 
				
					 code  | 
				
					 meanning  | 
				
					 Code  | 
				
					 Meaning  | 
			
| 
					 
  | 
				
					 DNxxx  | 
				
					 Diameter of the pipe is xxmm  | 
				
					 A  | 
				
					 Neoprene, PTFE  | 
				
					 1  | 
				
					 316 stainless steel  | 
				
					 Y  | 
				
					 Integrative  | 
				
					 S  | 
				
					 4~20Ma  | 
				
					 AC  | 
				
					 220VAC  | 
				
					 P06  | 
				
					 0.6MPa  | 
			
| 
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 B  | 
				
					 Polyurethane  | 
				
					 2  | 
				
					 316L stainless steel  | 
				
					 F  | 
				
					 Seperat  | 
				
					 R  | 
				
					 RS-485 (Modbus)  | 
				
					 DC  | 
				
					 24VDC  | 
				
					 P10  | 
				
					 1.0MPa  | 
			
| 
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 C  | 
				
					 PTFE  | 
				
					 3  | 
				
					 Hastelloy C  | 
				
					 
  | 
				
					 
  | 
				
					 H  | 
				
					 HART  | 
				
					 
  | 
				
					 
  | 
				
					 P16  | 
				
					 1..6MPa  | 
			
| 
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 P  | 
				
					 Profibus  | 
				
					 
  | 
				
					 
  | 
				
					 P25  | 
				
					 2.5MPa  | 
			
| 
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 M  | 
				
					 Modbus  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
			
| 
					 Example TFL-K1C10, Ball Level Meter with one point, 10m cable.  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
				
					 
  | 
			||||||||||
Contact Person: Miss.
Tel: 10-65569770
Fax: 86-10-8563-2312
Portable Ultrasonic Flow Meter, High Reliability Waterproof Flowmeter TUF-2000F
High Accuracy Portable Flowmeter , Online Ultrasonic Flow Meter TUF-2000S
TUF-2000H Handheld Ultrasonic Flow Meter, Non-Intrusive Measuring Flowemeter
Automatic Read Residential Plastic Multi Jet Water Meter With PDA/ Fixed Network
Plastic Nylon Multi Jet Super Dry Cold Water Meter ISO4064 Class B
Brass Multi Jet Domestic Water Meter Hot With End Flange / BSP LXSR-50E
YSI Pro20 Dissolved Oxygen METER and Temperature Handheld 6050020
Single Jet Water Meter Dry Dial LXSC-15D For Resident, Remote Reading Water Meter
Resident Rotary Domestic Single Jet Water Meter Anti Magnetic For Hot Water